• Security Systems > Camera > NW Camera ( feature ) > Are there any differences of heater performance in AeroPTZ camera, WV-SUD638, depending on power source, such as commercial power and Tested PoE injector (60 W)?
  • No : 6734
  • Open Date : 2018/01/17 16:34
  • Print

Are there any differences of heater performance in AeroPTZ camera, WV-SUD638, depending on power source, such as commercial power and Tested PoE injector (60 W)?

Answer

Yes.  There are some differences of heater performance depending on power source.
 
AeroPTZ camera, WV-SUD638, has built-in heaters and a defroster.
 
When the Tested PoE injector (60 W) is used,
  - Built-in heaters will not be started
  - A defroster will be started
  - A defroster will not be started when IR-LED is used.
 
When commercial power supply is used, both built-in heaters and a defroster will be started, including when IR-LED is used.  They are suitable at low temperature.
 
Therefore in the low-temperature environments such as -30 degrees Celsius (-22 degrees Fahrenheit) and less,
or in the region with strong wind and heavy snow, please use commercial power supply.
 
Please refer to the following URL for further details.
 
*Target models: WV-SUD638, WV-SUD638-H, WV-SUD638-T, WV-SUD638B, and WV-SUD638PJ
 
*PTZ: Pan, Tilt and Zoom